Shipping throughout Russia and to other countries

Intrinsic safety barriers passive series BI-02(D)P-XA. Intrinsic safety barriers passive series BI-02P-7A, BI-02DP-7A, BI-02P-9A, BI-02DP-9A, BI-02P-12A, BI-02DP-12A, BI-02P-15A, BI-02DP-15A, BI-02P-18A, BI-02DP-18A, BI-02P-24A, BI-02DP-24A of increased power are designed to ensure intrinsic safety through 2 independent channels of electrical circuits of measuring sensors. The barriers have the type of explosion protection "intrinsically safe electrical circuit" and the marking of explosion protection [Exia]I, [Exia]IIA.

BI-02(D)P-XHA. Technical specifications.

Intrinsic safety barriers BIB-02-12C, BIB-02-24C, BIB-02D-12C, BIB-02D-24C. Intrinsic safety barriers are passive 2-channel. A distinctive feature is a compact design, the function of an external fuse is implemented by an electronic circuit with the possibility of recovery after removing excess currents and voltages. Explosion protection category ExiaIIC.

BIB-02-12C, BIB-02-24C, BIB-02D-12C, BIB-02D-24C. Technical specifications.

Intrinsic safety barriers BIB-02R-12C, BIB-02R-24C, BIB-02DR-12C, BIB-02DR-24C. Intrinsic safety barriers are passive 2-channel. A distinctive feature is a compact design, the function of an external fuse is implemented by an electronic circuit with the possibility of recovery after removing excess currents and voltages. P-increased power. Explosion protection category ExiaIIB.

BIB-02R-12C, BIB-02R-24C, BIB-02DR-12C, BIB-02DR-24C. Technical specifications.

Intrinsic safety barriers BIB-02-12, BIB-02-24, BIB-02D-12, BIB-02D-24. Intrinsic safety barriers are passive 2-channel. They have an external replaceable fuse. Explosion protection category ExiaIIC.

BIB-02-12, BIB-02-24, BIB-02D-12, BIB-02D-2. Technical specifications.

Intrinsic safety barriers BIB-02-3, BIB-02-7, BIB-03-7, BIB-04-7. Intrinsically safe barriers are passive. The main application is thermocouples, thermistors, 2-, 3-, 4-wire circuits, sensor power, signal transmission with a voltage of ≤ 7V. Explosion protection category ExiaIIC (BIB-02-3, BIB-02-7), ExibIIC (BIB-03(4)-7.

BIB-02-3, BIB-02-7, BIB-03-7, BIB-04-7. Technical specifications.

Intrinsic safety barriers of increased power BIB-02(D)P-9,-12,-15,-18,-22,-24 Intrinsic safety barriers are passive 2-channel. A distinctive feature is that barriers are used for non-standard "voltages", P-increased power. Explosion protection category ExiaIIB.

BIB-02(D)P-24. Technical specifications.

BIB-02(D)P-12. Technical specifications.

BIB-02(D)P-15. Technical specifications.

BIB-02(D)P-18(22). Technical specifications.

BIB-02(D)P-9. Technical specifications.

Intrinsic safety barriers BI-RS-232 and BI-RS-485. Intrinsic safety barriers are passive 3-channel, 4-channel. The main application is the transmission of RS-232, RS-485 signals. Explosion protection category ExiaIIB.

BI-RS-232 and BI-RS-485. Technical specifications.

Intrinsic safety barriers BIB-04R-12C, BIB-04R-24C, BIB-04DR-12C, BIB-04DR-24C. Intrinsic safety barriers are passive 4-channel. A distinctive feature is a compact design, the function of an external fuse is implemented by an electronic circuit with the possibility of recovery after removing excess currents and voltages. P-increased power. Explosion protection category ExiaIIB.

BIB-04R-12C, BIB-04R-24C, BIB-04DR-12C, BIB-04DR-24C. Technical specifications.

Intrinsic safety barriers BIB-04-12C, BIB-04-24C, BIB-04D-12C, BIB-04D-24C. Intrinsic safety barriers are passive 4-channel. A distinctive feature is a compact design, the function of an external fuse is implemented by an electronic circuit with the possibility of recovery after removing excess currents and voltages. Explosion protection category ExiaIIC.

BIB-04-12C, BIB-04-24C, BIB-04D-12C, BIB-04D-24C. Technical specifications.

Intrinsic safety barriers BIB-04K-12S, BIB-04K-24S. Intrinsic safety barriers are passive 4-channel. The main purpose is to work with contact sensors of the S. K., O. K. type located in a dangerous zone. Explosion protection category ExiaIIB.

BIB-04K-12S, BIB-04K-24S. Technical specifications.

Intrinsic safety barriers BIB-08K-12S, BIB-08K-24S. Intrinsic safety barriers are passive 8-channel. The main purpose is to work with contact sensors of the S. K., O. K. type located in a dangerous zone. Explosion protection category ExiaIIB.

BIB-08K-12S, BIB-08K-24S. Technical specifications.

Intrinsic safety barriers BIB-08-12C, BIB-08D-12C, BIB-08-24C, BIB-08D-24C. Intrinsic safety barriers are passive 8-channel. A distinctive feature is a compact design, the function of an external fuse is implemented by an electronic circuit with the possibility of recovery after removing excess currents and voltages. Explosion protection category ExiaIIC.

BIB-08-12C, BIB-08D-12C, BIB-08-24C, BIB-08D-24C. Technical specifications.

Intrinsic safety barriers BIB-08R-12C, BIB-08R-24C, BIB-08DR-12C, BIB-08DR-24C. Intrinsic safety barriers are passive 8-channel. A distinctive feature is a compact design, the function of an external fuse is implemented by an electronic circuit with the possibility of recovery after removing excess currents and voltages. P-increased power. Explosion protection category ExiaIIB.

BIB-08R-12C, BIB-08R-24C, BIB-08DR-12C, BIB-08DR-24C. Technical specifications.

Questionnaire

All Avantaz products

The group "New Technologies" offers for review the products of the plant Avantaz: electronic equipment, instruments, measuring instruments for oil-producing, oil-refining and transportation companies
  • Intrinsic safety barriers Avantaz
    Intrinsic safety barriers
    BI-02I-GR, BIB-02IDR-GR, etc.
  • Intrinsic safety barriers Avantaz
    Intrinsic safety barriers
    BI-02(D)P-XHA,BIB-02(D)-XXC, etc.
  • Power supplies Avantaz
    Power supplies
    BI-IP-XX, BI-IP-XX-MX, etc.
  • Block modules Avantaz
    Block modules
    MB-DSGR-0X-XX series, etc.
  • Converters Avantaz
    Converters
    MB-PRS02GR-XX,TP-HAP-HGR, etc.
  • Battery, load balancers Avantaz
    Battery, load balancers
    LiFePO4, BAL-LTO, etc.
  • Turbine flow meters Avantaz
    Turbine flow meters
    TURBOSKAD and TURBOMID, etc.
  • Power supply systems Avantaz
    Power supply systems
    IMPULSE 3,4;BPE-XXX-XX, etc.
  • Printed circuit boards Avantaz
    Printed circuit boards
    development, installation, assembly, etc.

About Avantaz

AVANTAGE Center for Industrial and Technical Development (CPTR) was established in 2002. Main areas of activity
  • INNOVATIONS

    The company has a wide scientific and technical potential, has a number of inventions and patents for the production of modern electronic equipment, instruments, measuring instruments.
  • quality

    All products manufactured by the company are certified and licensed. Today, the company's products are successfully used at oil production, preparation, processing and transportation facilities.
  • relevance

    The work on the implementation of the devices is carried out in cooperation with leading design institutes of the oil-producing, oil-refining industries and transportation companies.

Information Board Avantaz

Learn more about our products Avantaz.
  • AVANTAGE price list бренда Авантаж
    AVANTAGE price list
  • Questionnaire for AVANTAGE products изготовителя Авантаж
    Questionnaire for AVANTAGE products

NEW TECHNOLOGIES GROUP

For sales and support please contact